WARNING !
Before taking any measurements, first connect the alligator clip of this probe to earth ground and make sure connection is electrically good.


Input impedance:1000MΩ
Division Ratio:1000 : 1
MAX. Test Voltage
DC : 0 ~ 40KV
AC : 1 ~ 28KV ( 50 / 60 Hz )
Safety APPL.
EN61010 UL3111-1 TUV / GS
IEC 1010 CAT II Pollution 2
Polarity:Positive / Negative
Accuracy
DC : ± 1% to 20KV
± 2 % to 40KV
AC : - 5 % to - 10 % ( 1 ~ 28KV ; 50 / 60Hz )
Temperature Cofficient:≦ 200ppm / ℃
Maximum loading Current:≦ 40μA ( at 40KV DC )
Maximum loading power:≦ 1.6 watt
Operating temperature:0 ℃ ~ + 50 ℃
Storage temperature:- 20 ℃ ~ + 70 ℃
Ground Lead length:90cm ( 3ft )
Output cable length:100cm ( 3.3ft )
For:DMM
Output Division:1V / 1KV
Dimensions:340mm x 80ψ
Weight:about 300g
Remark:For 10MΩ input impedance
DMM ( Accuracy < 0.5 % ) only.